Your plant already has the data. It does not have one place to put it.
Ask a plant what the OEE of Line 2 is right now, this minute, and
somebody can get you an answer by the end of the shift. The filler PLC
knew every bottle it ran. The historian logged it. The ERP had the
schedule before the shift started. None of it was missing. What was
missing was one place where it all came together, in one shape, with
one set of names, that any application could simply read.
This book closes that gap. It builds a unified namespace on one
reference site, a working bottling plant, from the first naming rule to
the last governance decision, using the tools a controls engineer
already has: MQTT as the transport, Sparkplug B as the industrial data
model over it, Ignition Edge and the central Ignition Gateway at both
ends, and the Cirrus Link modules that join them.
Nothing is left as an exercise. Four edge nodes get built, named, and
published. A broker gets secured. A Gateway consumes the whole
namespace and turns it back into a site model the enterprise can read.
When a node dies, you see exactly what the operator sees and why that
is better than the alternative.
What you will learn: what data transformation actually is, and why
point-to-point integration stops scaling at about seven systems; naming
rules that survive a PLC replacement, a new line, and the engineer who
comes after you; MQTT in enough depth to configure and troubleshoot it,
quality of service, retained messages, wills, keep alive, and sessions;
Sparkplug B in full, the topic namespace, birth and death certificates,
session state, metrics and templates, store and forward, and why
retained messages are forbidden; a complete build in Ignition, module
by module, Transmission at the edge, a hardened broker, Engine at the
center, and Ignition UDTs mapped onto Sparkplug templates so the asset
model is built once; how to live with the sources that will never speak
Sparkplug, with flat 3.1.1 topics running alongside the namespace
without spoiling it; normalizing units, names, and state codes into one
site model, with quality that propagates so a derived number is never
good while its inputs are stale; and running it afterward, TLS and
access control lists, watching the wire, feeding the enterprise, and
keeping the namespace under control as it grows.
Who it is for: integrators, controls engineers, SCADA administrators,
and plant IT staff who are tired of being quoted a project every time
somebody needs
Details
- Publication Date
- Oct 24, 2026
- Language
- English
- ISBN
- 9798998323126
- Category
- Engineering
- Copyright
- All Rights Reserved - Standard Copyright License
- Contributors
- By (author): Charles Vance
Specifications
- Pages
- 306
- Binding Type
- Paperback Perfect Bound
- Interior Color
- Black & White
- Dimensions
- US Trade (6 x 9 in / 152 x 229 mm)